EDWARD SYSTEM TECHNOLOGY 3. GENERATION
How to EST 3 Trouble Solution Very Easy step by step or work Experience This system is excellent and very easy
The Default EST 3 /EST2/EST -Password for every level.
Access Level…………….>……….Default Password
Level. 2……………………………..>………….2222
Level.3…………………………….>……………3333
Level.4 ……………………………>……………4444
How to change the password. Press the command MENU option. Now go to the program and choose Edit password. Select the level and Enter a new 4- 4-digit password. to confirm you Enter a valid user access password.
EST 3 All Fault
COMMAN>Trouble ACT | Need to check the Device or Module there is no Voltage in Device or Module |
Dirty Head ACT 100% | Need to clean After cleaning wait 8 to 10 hours to reset |
Dirty ACT Above60% | Need to clean After cleaning wait 8 to 10 hours to reset |
Mapping Fault | Need programming |
Bad Type Act | Need programming |
Bad pastry | Need programming |
Open fault(Module Fault) | Need to check the Module End Of Line Resistor |
Open short | Need to check Loop There is some Lose Connection |
Battery fault(power) | Need to check Battery States Or Voltage Need 12 V DC to 14 V DC |
Ground faults | Need to check Loop 01 BY 01 Device And Module |
Loop short / Network fault | Need to check Full Loop Networking and networking cable |
If all devices Show trouble’s Need to check the Loop card. First Remove the Loop From the card. if you check the loop card voltage if the voltage not coming then the card is Faulty 14/20 voltage is normal (SD.10 Voltage is working normally)
LOOP Capacity
PANEL-CAB-5 | 4. LOOPS |
PANEL-CAB-7 | 8. LOOPS |
PANEL-CAB-14 | 8. LOOPS |
1. LOOP | 125 device + 125 Module |
Sounder | conventional use in (CC1.Module) |
FIRE TELEPHONE + ZONE+AMP
CAB21+Extra Power Card(3pps)
BATTERY CAPACITY
7. AH TO 100. AH.
NOTE: if there is power supply card 02 then we are using 100. AH
If 1. power supply card then we can use 7. AH TO 63. AH
Fire Telephone
fire telephone using in (EST.3 ar EST.4) Have separate loop From Fire Telephone to the card then go to connection.
How to Enable/disable EST 3
Go to command MANU>Disable or Enable on the Fire panel press. Disable the button from the fire panel screen.
giving option> allow Zone /Device/Sounder and Output to be Disable or Enable
Select the up-down button on the touchscreen Display and more options in the Description below.
DATE AND TIME SETTING
Configuring system time & date is compulsory if you want to keep track of any changes. also, the time and date need to be set.
On the EST3panel solution
same format for (date and time is set in 24 Hours (HHMMSS)and(MMDDYY)
Go to the Command MENU and then choose the program “ change the time and date you see the 24-hour format given there Enter the time using a valid user access password.
THE Command sequence for changing Holiday is first command >MENU>PROGRAM>EDIT Holiday. The rest of the process is the same
RESTART THE PANEL.
To restart the panel go to the restart processes Here’s how to do Restart The Panel
Solution
push the first command menu button select the program follow the by-step Restart. Now your front shows an option for restarting a single panel ar all panels will come forward.
To restart a single panel you have to provide the address of the target panel.it is a 2.-digit number (pp) Give the user access password to complete the process.
for restarting all panels no need to provide any panel address separately
Smoke Detector’s Sensitive Level
The smoke detectors have different types of sensor levels .it can be a dual sensor.(FSP-851 ar FSP-951) However, the sensitivity of the smoke detector is controlled by the fire Alarm panel.
The smoke detector got a 2. level of sensitivity.1 primary sensitivity and the other alternative sensitivity.During regular Hours. the primary sensitivity level is implemented by the system.
But when the premiss a time control reconfigures then use their alternative sensitivity level.
command MENU can be used to physically switch between both sensitivity levels.
You can activate the primary sensitive to switch to the alternate sensitivity you restart the primary sensitive to change to sensitivity.
solution
Push the button command MENU and select Activate. You will see the ALT sensitivity option. Select it and give access by providing the password.
The fire panel is 1 of the most important components in the make sure to handle it with the Take professional help if necessary all practical work Alam & GousPak
Conclusion
In conclusion. the EST3 fire alarm system stands out as a reliable and efficient solution for safeguarding lives and property. its advanced features, coupled with real-world. success stories, make it a top choice in the market.
Asked Question about the EST3 Fire Alarm System?
How Does the EST3 System Detect Fires?
The EST3 System utilizes (insert detection technology)and reliable and early detection of fire.
Can it be integrated with existing security systems?
Yes, the EST3 system is designed for seamless integration with various security systems, providing a comprehensive security solution.
What is the average response time of the EST3 system?
The EST3 system boasts an impressive response time, typically response time ensuring swift Action in Emergency.
ALAM ZEB (EST.Specialist)